+84 979.349.375

Chào mừng quý khách đến với Flowmeters Vietnam

Hỗ trợ trực tuyến


Skype Me™!
Sale & Tech Support
tu@pitesvietnam.com
0979.349.375

 

Thăm dò ý kiến

Bạn quan tâm đến yếu tố nào khi lựa chọn Flowmeters Vietnam?
1. Chất lượng, 0 votes (0 %)
2. Giá cả, 0 votes (0 %)
3. Phong cách phục vụ, 0 votes (0 %)
4. Thân thiện, 1 vote (100 %)
Total votes: 1

Thống kê website

  • Thành viên online Thành viên online
    • Tổng cộng Đang online 3
    • Khách Khách 3
    • Thành viên Thành viên 0
    • Tổng cộng Lượt truy cập 2136179

Bảng giá

53H80-A00B1AA0ABAA 

Đăng bởiAdmin

53H80-A00B1AA0ABAA - Endress Hauser Vietnam

 

 

  Proline Promag 53H
Electromagnetic flowmeter

The flowmeter for smallest flow rates with flexible system integration

Electromagnetic flowmeter - Proline Promag 53H

Promag H is the preferred sensor for applications with highest requirements in the food & beverage and life science industries. Combined with the Promag 53 transmitter with touch control, four line display and extended functionality like software options for filling and dosing, electrode cleaning or advanced diagnostics, Promag 53H offers highest accuracy in the most complex and demanding measuring tasks. Promag 53H is available in a compact or remote version.

 

  • Flexible installation concept – numerous hygienic process connections

  • Energy-saving flow measurement – no pressure loss due to cross-section constriction

  • Quality – software for filling and dosing, density, electrode cleaning and also advanced diagnostics

  • Easy calculation – bidirectional totalizers

  • Automatic recovery of data for servicing

  • Maintenance-free – no moving parts

  • Field of application

    • The measuring principle is virtually independent of pressure, density, temperature and viscosity

    • For demanding hygienic applications.

    Device properties

    • Liner made of PFA

    • Sensor housing made of stainless steel (3A, EHEDG)

    • Wetted materials CIP, SIP cleanable

    • 4-line backlit display with touch control

    • Device in compact or remote version

    • HART, PROFIBUS PA/DP, Modbus RS485, FF, EtherNet/IP

    • Liquids

      Measuring Principle Electromagnetic
      Product headline The flowmeter for smallest flow rates with flexible system integration. For demanding hygienic applications.
      Sensor features Flexible installation concept – numerous hygienic process connections. Energy‐saving flow measurement – no pressure loss due to cross‐section constriction. Maintenance‐free – no moving parts. Liner made of PFA. Sensor housing made of stainless steel (3-A, EHEDG).
      Transmitter features Quality – software for filling & dosing, density, electrode cleaning and also advanced diagnostics. Easy calculation – bidirectional totalizers. Automatic recovery of data for servicing. 4‐line backlit display with touch control. Device in compact or remote version.
      Nominal diameter range DN 2...150
      1/12"...6"
      Max. measured error ±0.2%
      Measuring range 0...600 m3/h
      Max. process pressure PN16...40
      Medium temperature range -20...+150°C
      (-4...+302°F)
      Ambient temperature range -20...+60°C
      -40...+60°C (optional)
      Degree of protection IP 67 (NEMA 4x)
      Display/Operation Four line display with backlit
      Touch control
      Outputs 4...20 mA
      Pulse / frequency(active/passive)
      Relais
      Status
      Inputs Status
      Current input
      Digital communication HART
      PROFIBUS PA
      Profibus DP
      FOUNDATION Fieldbus
      Hazardous area approvals ATEX
      FM
      CSA
      TIIS
    Technical Information (TI) Operating Instruction (BA/KA)
    Conversion Instruction (UA) Mounting Instruction (EA)
    Ex Safety Instructions (XA) Special Documentation (SD)
    Manufacturer Information (MI) Customer Magazine (CM)
    Industry Solutions (SO) Fields of Activities (FA)
    Competence Brochure (CP) Case Studies (CS)
    Innovations (IN) System Partner (SP)
    Tender Text Device Drivers
    Certificates
     
     
    All available downloads

    All Spare parts

    Nr Order code Specification
    F 50096745 Kit P.s.b. 50/51/53 85-260VAC
    F 71039466 Kit p.s.b. 50/53 85-260VAC HE
    HE = harsh environment
     
    F 71039466 Kit p.s.b. 50/53 85-260VAC HE
    HE = harsh environment
     
    F 50096746 Kit P.s.b. 50/51/53 85-260VAC Ex
    F 71039467 Kit p.s.b. 50/53 85-260VAC HE Ex
    HE = harsh environment
     
    F 50096747 Kit P.s.b. 50/51/53 20-55VAC 16-62VDC
    F 71039468 Kit p.s.b.50/53 20-55VAC 16-62VDC HE
    HE = harsh environment
    F 50096744 Kit P.s.b. 50/51/53 20-55VAC16-62VDC Ex
    F 71039469 Kit p.s.b.50/53 20-55VAC 16-62VDC HE Ex
    HE = harsh environment
     
    7 50094002 Kit 10 fuses 250 VAC T800 MA
    7 50094003 Kit 10 fuses 250 VAC T 2A00
    B 50106088 Kit meas. amplifier PMAG 53 WEA EX
    Language: FR, ES, IT, NL, PT, DE, EN
    B 71039458 Kit meas. amplifier 53 WEA HE Ex
    Language: FR, ES, IT, NL, PT, DE, EN
    HE = harsh environment

     
    B 50106085 Kit meas. amplifier PMAG 53 WEA
    Language: FR, ES, IT, NL, PT, DE, EN
    B 71039454 Kit meas. amplifier 53 WEA HE
    Language: FR, ES, IT, NL, PT, DE, EN
    HE = harsh environment


     
    B 50106090 Kit meas. amplifier PMAG 53 SEA EX
    Language: JA, ID, EN
    B 71039460 Kit meas. amplifier 53 SEA HE Ex
    Language: JA, ID, EN
    HE = harsh environment

     
    B 50106087 Kit meas. amplifier PMAG 53 SEA
    Language: JA, ID, EN
    B 71039456 Kit meas. amplifier 53 SEA HE
    Language: JA, ID, EN
    HE = harsh environment

     
    B 50106089 Kit meas. amplifier PMAG 53 EES EX
    Language: SV, FI, NO, RU, PL, CS, EN
    B 71039459 Kit meas. amplifier 53 EES HE Ex
    Language: SV, FI, NO, RU, PL, CS, EN
    HE = harsh environment

     
    B 50106086 Kit meas. amplifier PMAG 53 EES
    Language: SV, FI, NO, RU, PL, CS, EN
    B 71039455 Kit meas. amplifier 53 EES HE
    Language: SV, FI, NO, RU, PL, CS, EN
    HE = harsh environment


     
    B 50108134 Kit meas. amplifier Pmag 53 CN EX
    CN= language ZH + EN
    B 71039461 Kit meas. amplifier 53 CN HE Ex
    Language: ZH, EN
    HE = harsh environment

     
    B 50108133 Kit meas. amplifier Pmag 53 CN
    CN= language ZH + EN
    B 71039457 Kit meas. amplifier 53 CN HE
    Language: ZH, EN
    HE = harsh environment

     
    B 71261676 Kit amp. 53, HART7, DE+FR+IT+ES+EN, EX
    Language: DE+FR+IT+ES+EN
     
    B 71261679 Kit amp. 53,HART7, DE+FR+IT+ES+EN, HE,EX
    Language: DE+FR+IT+ES+EN
    HE = harsh environment

     
    B 71261680 Kit amp. 53, HART7, DE+FR+IT+ES+EN
    Language: DE+FR+IT+ES+EN
     
    B 71261682 Kit amp. 53, HART7, DE+FR+IT+ES+EN, HE
    Language: DE+FR+IT+ES+EN
    HE = harsh environment

     
    B 71261684 Kit amp. 53, HART7, RU+NL+PT+CS+EN, EX
    Language: RU+NL+PT+CS+EN
     
    B 71261685 Kit amp. 53,HART7, RU+NL+PT+CS+EN, HE,EX
    Language: RU+NL+PT+CS+EN
    HE = harsh environment

     
    B 71261686 Kit amp. 53, HART7, RU+NL+PT+CS+EN
    Language: RU+NL+PT+CS+EN
     
    B 71261687 Kit amp. 53, HART7, RU+NL+PT+CS+EN, HE
    Language: RU+NL+PT+CS+EN
    HE = harsh environment

     
    B 71261688 Kit amp. 53, HART7, ZH+PL+ID+EN, EX
    Language: ZH+PL+ID+EN
     
    B 71261689 Kit amp. 53, HART7, ZH+PL+ID+EN, HE, EX
    Language: ZH+PL+ID+EN
    HE = harsh environment

     
    B 71261690 Kit amp. 53, HART7, ZH+PL+ID+EN
    Language: ZH+PL+ID+EN
     
    B 71261692 Kit amp. 53, HART7, ZH+PL+ID+EN, HE
    Language: ZH+PL+ID+EN
    HE = harsh environment

     
    B 71261693 Kit amp. 53, HART7, JA+SV+NO+FI+EN
    Language: JA+SV+NO+FI+EN
     
    B 71261694 Kit amp. 53, HART7, JA+SV+NO+FI+EN, HE
    Language: JA+SV+NO+FI+EN
    HE = harsh environment

     
    C 50098302 Kit commodul Iout passive/Frequency Exi
    50/53/40/8X/93/65
    C 71039479 Kit I/O Iout passive/Frequency HE Exi
    50/53/8X
    HE = harsh environment

     
    C 50098303 Kit commodul Iout active/Frequency Exi
    50/53/40/8X/93/65
    C 71039478 Kit I/O Iout active/Frequency HE Exi
    50/53/8X
    HE = harsh environment

     
    C 50098300 Kit commodul current/freq./2Relay Ex
    53/55/83/93/65
    C 71039475 Kit I/O current/frequency/2Relay HE EX
    53/55/83
    HE = harsh environment

     
    C 50098301 Kit com 53/55/83/93 curr./freq. out Ex
    C 71039476 Kit I/O current/frequency out HE EX
    53/55/83
    HE = harsh environment

     
    C 71066579 Kit I/O Profibus PA Ex
    50/53/55/80/83/93/65
    C 71066580 Kit I/O 50/53/55/80/83 Profib. PA HE Ex
    HE = harsh environment
    C 50101264 Kit I/O Foundation Fieldbus C02 Ex
    53/55/83/93
    C 71095035 Kit I/O Foundation Fieldbus C14 EX
    53/55/83/93/65
    C 50101264 Kit I/O Foundation Fieldbus C02 Ex
    53/55/83/93
    C 71095035 Kit I/O Foundation Fieldbus C14 EX
    53/55/83/93/65
    C 71039483 Kit I/O Foundation Fieldbus HE C02 EX
    53/55/83
    HE = Harsh Environment

     
    C 71095037 Kit I/O Foundation Fieldbus HE C14 EX
    53/55/83
    HE = Harsh Environment

     
    C 71021742 Kit I/O 50/53/55/83/65/8ME Profib. DP Ex
    C 71039484 Kit I/O 50/53/55/83 Profibus DP HE EX
    HE = harsh environment
     
    D 71021743 Kit Com ModbusRS485+stat.In 2Interf.Ex
    53/83/84/65/8CN/8DF
    D 71039485 Kit I/O Modb.RS485+Stat.In 2Interf.HE EX
    53/83/84/8CN/8DF
    HE = Harsh environment
    D 50108002 Kit I/O Profib. DP+Stat.In 2 Interf. Ex
    53/55/83/93
     
    D 71039486 Kit I/O Profib.DP+Stat.In 2 Interf.HE EX
    53/55/83
    HE = harsh environment

     
    D 50096833 Kit Commodul current out 3 Interface Ex
    53/55/8X/93/65
    D 71039477 Kit I/O current out 3 Interface HE EX
    53/55/8X
    HE = harsh environment

     
    D 71105712 Kit I/O Modul 53/83 Ethernet
    Including Subprint Ethernet
    2 50096834 Kit Sub PCB current out
    53/55/8X/93/65
    2 71039487 Kit Sub PCB current out HE
    53/55/8X
    HE = harsh environment

     
    3 50096835 Kit Sub PCB frequency out
    53/55/80/83/93/65
    3 50096835 Kit Sub PCB frequency out
    53/55/80/83/93/65
    3 71039489 Kit Sub PCB frequency out HE
    53/55/80/83
    HE = harsh environment

     
    3 71039489 Kit Sub PCB frequency out HE
    53/55/80/83
    HE = harsh environment

     
    4 50096837 Kit Sub PCB Status input
    53/55/8X/93/65
    4 71039492 Kit Sub PCB Status input HE
    53/55/8X
    HE = harsh environment

     
    5 50096836 Kit Sub PCB Relay out
    53/55/83/84/93/8CN/8DF
    5 50096836 Kit Sub PCB Relay out
    53/55/83/84/93/8CN/8DF
    5 71039491 Kit Sub PCB Relay out HE
    53/55/83/84/8CN/8DF
    HE = Harsh environment
    5 71039491 Kit Sub PCB Relay out HE
    53/55/83/84/8CN/8DF
    HE = Harsh environment
    6 50098562 Kit Sub PCB current in
    53/55/83/65
     
    6 71039488 Kit Sub PCB current input HE
    53/55/83
    HE = harsh environment

     
    37 71105711 Kit Sub PCB 53/83 Ethernet
    J 50096755 Kit display modul Wall enclosure
    53/55/83/84/93/8CN/8DF
    E 50096754 Kit display module
    53/55/83/84/93/8CN/8DF
    21 50094017 Kit Bus PCB/PCB carr.5X/8X/9X/65 wall
    H 50099099 Kit Bus/connec.b.5X/8X SS-housing
    G 50094016 Kit Bus/connec.b.5X/40/8X/65 field hous.
    G 71105709 Kit Bus/connec. board 53/83 Ethernet
    19 50094015 Kit connec. board PMAG5X wall enclo.
    19 71039496 Kit connec. board 50/53/55 wall encl.HE
    HE = harsh environment
     
    18 50094014 Kit connec. board In/Output Wall encl
    29 50108139 Kit Termin.Block field hous. 5X/8X/40/65
    30 50108140 Kit Termin.Block Wall encl. 5X/8X/9X/65
    1 50094004 Kit T-DAT Transmitter Data Chip
    S 71003948 Kit S-Dat Promag 53 programmed
    Serialnumber is forceful required
    17 50099100 Kit Cover 5X/8X with window SS-housing
    8 50094027 Kit Cover 5X/40/8X/93/65 with window Exd
    8 50094026 Kit Cover 5X/40/8X/65 with window
    9 50094029 Kit Cover 5X/40/8X/93/65 vers. blind Exd
    9 50094028 Kit Cover 5X/40/8X/65 version blind
    10 50094040 Kit Cover 5X/40/8X/93/65 Conn.termi.Exd
    10 50094039 Kit Cover 5X/40/8X/93/65 Conn.termi.Exe
    10 50094038 Kit Cover Connection terminal
    10/5X/40/8X/93/65/400/800
      71309084 Cover repair kit for G04
    Usage: 10H,50H,53H,55H
    15 50098036 Kit 10 cable glands M20x1.5 Ex
    15 50098036 Kit 10 cable glands M20x1.5 Ex
    15 50098036 Kit 10 cable glands M20x1.5 Ex
    15 50096840 Kit 10 cable glands M20x1,5
    15 50098040 Kit 10 extension M20x1.5/PG13,5
    15 50098042 Kit 10 ext. M20x1.5/NPT 1/2" (plug PVC)
    15 50098042 Kit 10 ext. M20x1.5/NPT 1/2" (plug PVC)
    15 50098041 Kit 10 ext. M20x1.5/G 1/2" (plug PVC)
    15 50098041 Kit 10 ext. M20x1.5/G 1/2" (plug PVC)
    15 50098037 Kit Cable gland Profibus PA
    15 50094984 Kit Cable gland Found. Fieldbus
    15 71105713 Kit 1 Bus connector 53/83 Ethernet
    15 71105713 Kit 1 Bus connector 53/83 Ethernet
    12 50096839 Kit Circuit board cpl field/SS-housing
    14 50099102 Kit Bushing to field/SS-housing
    13 50096841 Kit Ground terminal / Cover clamp
    20 50094041 Kit Seal cover to Wall enclosure
    11 50094050 Kit 10 Seal cover to field housing
    16 50099101 Kit housing gaskets SS-Field housing
    23 50098020 Kit parts housing compact Stnd/HT
    Usage:
    10/23/50/51/53/55
    Sensor: D/E/H/L/P/S/W

     
    25 50098019 Kit parts housing FS Stnd/HT
    Usage:
    10/50/51/53/55/400/800
    Sensor: D/E/H/L/P/S/W

     
    22 50098021 Kit housing gaskets H compact
    24 50098022 Kit housing gaskets H FS
      71129286 Kit 8 special screws M6 Promag H DN25
    M6x16/5,0 6kt, ISO4017 A2
      50098801 Fieldcheck verification/simulation syst.
    Universal verification and simulation
    system for routine verification of
    all E+H Proline flowmeters (incl.
    outputs) and simulation of the primary
    sensor signals.
    By means of the software FieldCare
    device set up, the verification results
    can easily be documented.
    To connect Fieldcheck to a personal
    computer a serial interface cable
    (RS 232C) is included.

    Delivery with:
    Power supply unit 85-260 VAC
    NiMH-AccuPack
    Softcase
    Connection cable for Simubox
    Connection cable Fieldcheck/Proline dev.
    Test leads current/frequency
    Serial interface cable (RS 232C)
      DK5CA- Promag, cable remote version
    10/50/51/53/55/400/800
    1 kit includes 1 coil cable and
    1 signal cable
      Cable, Remote Version:
    1 5m/15ft
    2 10m/30ft
    4 ..... m
    5 ..... ft
      Approval:
    A Non-hazardous area + ATEX II 3G, FM/CSA
    B ATEX II2GD, TIIS Zone 1
      53XXX- Promag 53, transmitter
      Application:
    XXX Promag 53W, 53P, 53H, 53L, 53E
      Version:
    XX Transmitter only
      Approval:
    A Non-hazardous area
    B ATEX II 2GD+ IECEx Z1,21; Ex d wiring, Ex deia IIC, Ex tD A21 Z=Zone
    D ATEX II 2GD+ IECEx Z1,21; Ex e wiring, Ex deia IIC, Ex tD A21 Z=Zone
    H ATEX II 3G EEx nRC
    J ATEX II 3G Ex nA nC IIC
    N FM XP Cl. I Div. 1 / CSA Cl. I Div. 1
    R FM NI Cl. I Div. 2 / CSA Cl. I Div. 2
      Housing:
    1 Compact Alu, IP67 NEMA4X, -40oC/oF Sensor see specification
    2 Compact stainless, IP67 NEMA4X, -40oC/oF Sensor see specification
    3 Wall Alu, IP67 NEMA4X, -40oC/oF Sensor see specification
    9 Special version, TSP-no. to be spec.
    A Compact Alu, IP67 NEMA4X
    B Compact stainless, IP67 NEMA4X
    C Wall Alu, IP67 NEMA4X
    G Field Alu, IP67 NEMA4X
    P Compact Alu, IP67 NEMA4X, HE HE= harsh environment
    R Compact stainless, IP67 NEMA4X, HE HE= harsh environment
    S Wall Alu, IP67 NEMA4X, HE HE= harsh environment
    T Field Alu, IP67 NEMA4X, HE HE= harsh environment
      Cable, Remote Version:
    0 Not used
    1 5m/15ft coil and signal cable
    2 10m/30ft coil and signal cable
    4 ..... m coil and signal cable
    5 ..... ft coil and signal cable
    9 Special version, TSP-no. to be spec.
      Cable Entry:
    9 Special version, TSP-no. to be spec.
    A Gland M20 (EEx d > thread M20)
    B Thread NPT 1/2
    C Thread G 1/2
    K Bus plug + gland M20
    L Bus plug + thread NPT 1/2
    M Bus plug + thread G 1/2
    Q 2 x Bus plug + gland M20
    R 2 x Bus plug + thread NPT 1/2
    S 2 x Bus plug + thread G 1/2
      Power Supply; Display:
    4 HART 7; 85-260VAC; Language ZH+PL+ID+EN; 4-line + Touch control
    5 HART 7; 20-55VAC /16-62VDC; Language ZH+ PL+ID+EN; 4-line +Touch control
    7 85-260VAC, WEA, w/o display, Remote configuration WEA= language DE+EN+FR+IT+ES+PT+NL
    8 20-55VAC / 16-62VDC, WEA, w/o display, Remote configuration WEA= language DE+EN+FR+IT+ES+PT+NL
    9 Special version, TSP-no. to be spec.
    A 85-260VAC, WEA, 4-line + Touch control WEA= language DE+EN+FR+IT+ES+PT+NL
    B 20-55VAC / 16-62VDC, WEA, 4-line + Touch control, WEA= language DE+EN+FR+IT+ES+PT+NL
    C 85-260VAC, SEA, 4-line + Touch control SEA= language JA+ID+EN
    D 20-55VAC / 16-62VDC, SEA, 4-line + Touch control, SEA= language JA+ID+EN
    E 85-260VAC, EES, 4-line + Touch control EES= language SV+FI+NO+RU+PL+CS+EN
    F 20-55VAC / 16-62VDC, EES, 4-line + Touch control, EES= language SV+FI+NO+RU+PL+CS+EN
    G 85-260VAC; CN, 4-line + Touch control, CN= language ZH + EN
    H 20-55VAC / 16-62VDC; CN, 4-line + Touch control, CN= language ZH + EN
    P HART 7; 85-260VAC; Language DE+FR+IT+ES+ EN; 4-line + Touch control
    Q HART 7; 20-55VAC /16-62VDC; Language DE+ FR+IT+ES+EN; 4-line +Touch control
    R HART 7; 85-260VAC; Language RU+NL+PT+CS+ EN; 4-line + Touch control
    S HART 7; 20-55VAC /16-62VDC; Language RU+ NL+PT+CS+EN; 4-line +Touch control
    T HART 7; 85-260VAC;Language JA+SV+NO+FI+ EN; 4-line + Touch control
    U HART 7; 20-55VAC /16-62VDC; Language JA+ SV+NO+FI+EN; 4-line +Touch control
      Adjustment; Software Feature:
    A Factory setup; basic version
    C Factory setup; ECC electrode cleaning circuit
    J Factory setup; Batching
    L Factory setup; Batching+ECC electrode cleaning circuit
      Output, Input:
    2 4-20mA SIL HART + freq.+relay+20mA out, modules exchangeable
    4 4-20mA SIL HART + freq.+relay+20mA in, modules exchangeable
    5 4-20mA SIL HART + freq.+20mA In+stat.In, modules exchangeable
    7 Modbus RS485 + 2x relay + stat.In M= modules exchangeable
    A 4-20mA SIL HART + frequency
    B 4-20mA SIL HART + freq. + 2x relay
    C 4-20mA SIL HART + freq. + 2x relay M= modules exchangeable
    D 4-20mA SIL HART + freq.+ relay+stat.In, modules exchangeable
    F PROFIBUS PA, Ex-i
    G FOUNDATION Fieldbus, Ex-i
    H PROFIBUS PA
    I EtherNet/IP
    J PROFIBUS DP
    K FOUNDATION Fieldbus
    L 4-20mA SIL HART + 2x relay + stat.In, modules exchangeable
    M 4-20mA SIL HART + 2x freq. + stat.In, modules exchangeable
    N Modbus RS485 + 20mA +freq.+stat.In, modules exchangeable
    P PROFIBUS DP + 20mA + freq.+ stat.In, modules exchangeable
    Q Modbus RS485 + stat.In
    S 4-20mA SIL HART active + freq., Ex-i, freq. = passive
    T 4-20mA SIL HART passive + freq. Ex-i, freq. = passive
    V PROFIBUS DP + 2x relay + stat.In, modules exchangeable
      DK5WM- Transmitter Promag, mounting set
    10/50/51/53/55/800
      Application:
    A Remote, wall / pipe mounting, panel
    B Remote, field Tube 3/4 - 3inch
      DK5UI- Promag 53, retro fit kit In/Output
    A retrofit kit consists of an
    instruction sheet,
    meter documentation, retrofit label,
    connection
    label and the exchangeable I/O modules.

     
      Exist. I/O Modul:
    2 4-20mA SIL HART + freq.+relay+20mA out
    4 4-20mA SIL HART + freq.+relay+20mA in
    5 4-20mA SIL HART + freq.+20mA In+stat.In
    7 Modbus RS485 + 2x relay + stat.In
    C 4-20mA SIL HART + freq. + 2x relay
    D 4-20mA SIL HART + freq.+ relay+stat.In
    L 4-20mA SIL HART + 2x relay + stat.In
    M 4-20mA SIL HART + 2x freq. + stat.In
    N Modbus RS485 + 20mA +freq.+stat.In
    P PROFIBUS DP + 20mA + freq.+ stat.In
    V PROFIBUS DP + 2x relay + stat.In,
      New I/O Modul:
    2 4-20mA SIL HART + freq.+relay+20mA out
    4 4-20mA SIL HART + freq.+relay+20mA in
    5 4-20mA SIL HART + freq.+20mA In+stat.In
    7 Modbus RS485 + 2x relay + stat.In
    C 4-20mA SIL HART + freq. + 2x relay
    D 4-20mA SIL HART + freq.+ relay+stat.In
    L 4-20mA SIL HART + 2x relay + stat.In
    M 4-20mA SIL HART + 2x freq. + stat.In
    N Modbus RS485 + 20mA +freq.+stat.In
    P PROFIBUS DP + 20mA + freq.+ stat.In
    V PROFIBUS DP + 2x relay + stat.In,
      Approval:
    A Non-hazardous area
    B ATEX
    N FM/CSA
      DK5SO- Promag 53/55, software package
      Application:
    B Batching
    C ECC electrode cleaning circiut
      53H- Promag 53H
    Electromagnetic flowmeter
    PFA liner
      Nominal diameters
    02 DN02 1/12"
    04 DN04 5/32"
    08 DN08 5/16"
    15 DN15 1/2"
    1F DN150 6"
    1H DN100 4"
    1Z DN125
    22 DN25 1" ODT, SMS, ANSI, ISO pipes
    26 DN25 DIN, JIS pipes
    40 DN40 1 1/2"
    50 DN50 2"
    65 DN65 2 1/2"
    80 DN80 3"
      Process Connection:
    0 Clamp DIN32676, 316L/1.4404
    1 Tri-Clamp, 316L/1.4404
    2 DIN11851, 316L/1.4404
    3 Aseptic DIN11864-1A, 316L/1.4404
    4 Aseptic DIN11864-2A, 316L/1.4404
    5 SMS1145, 316L/1.4404
    6 ISO2853, 316L/1.4404
    9 Special version, TSP-no. to be spec.
    A Not used
    B Welding nipple EN ISO1127, 316L/1.4404 (DIN2501)
    C Welding nipple ODT/SMS, 316L/1.4404, O= O-ring
    D PN40, 316L/1.4404, flange EN1092-1
    E Cl.150, 316L/1.4404, flange ANSI B16.5
    F 20K, SUS 316L, flange JIS B2220
    G PN16, PVDF, flange EN1092-1 (DIN2501)
    H Cl.150, PVDF, flange ANSI B16.5
    J 10K, PVDF, flange JIS B2220
    K Male thread ISO228, 316L/1.4404
    L Female thread ISO228, 316L/1.4404
    M Hose adapter ID=13mm, 316L/1.4404
    N Hose adapter ID=16mm, 316L/1.4404
    P Hose adapter ID=19mm, 316L/1.4404
    R Adhesive fitting tube 1/2", PVC
    S Adhesive fitting 20x2mm tube, PVC
    W Clamp ISO2852, 316L/1.4404
      Seal:
    0 Not used
    9 Special version, TSP-no. to be spec.
    A O-ring, EPDM
    B O-ring, Viton
    C O-ring, Kalrez
    F Aseptic shape, EPDM
    G Aseptic shape, Viton
    H Aseptic shape, Silicone
      Electrodes:
    0 1.4435/316L
    1 Alloy C-22
    2 Tantalum
    5 Platinum
    9 Special version, TSP-no. to be spec.
    A 1.4435/316L + grounding rings
    B Alloy C-22 + grounding rings
    D Tantalum + grounding rings
    G 1.4435/316L, bullet nose
      Calibration:
    9 Special version, TSP-no. to be spec.
    B 0.2%
    E 0.2%, 3-point, traceable ISO/IEC17025
      Additional Test, certificate:
    1 w/o
    2 Mat. certificate (flange)
    3 pressure test
    4 Mat. certificate (flange) + pressure test
    5 CRN approval
    8 CRN approval + mat. certicate (flange) + pressure test
    9 Special version, TSP-no. to be spec.
    E EAC marking
    N EAC marking + mat. certificate (flange)
    P PED Cat. II/III
    R PED Cat. II/III + mat. certificate (flange)
      Approval:
    A Non-hazardous area
    B ATEX II 2GD+ IECEx Z1,21; Ex d wiring, Ex deia IIC, Ex tD A21 Z=Zone
    D ATEX II 2GD+ IECEx Z1,21; Ex e wiring, Ex deia IIC, Ex tD A21 Z=Zone
    H ATEX II 3G EEx nRC
    J ATEX II 3G Ex nA nC IIC
    K NEPSI Ex de IIC, wiring Ex d
    N FM XP Cl. I Div. 1 / CSA Cl. I Div. 1
    R FM NI Cl. I Div. 2 / CSA Cl. I Div. 2
    S NEPSI Ex de IIC, wiring Ex e
    U TIIS Zone 1
      Housing:
    1 Compact Alu, IP67 NEMA4X, -40oC/oF Sensor see specification
    2 Compact stainless, IP67 NEMA4X, -40oC/oF Sensor see specification
    3 Wall Alu, IP67 NEMA4X, -40oC/oF Sensor see specification
    4 Compact stainless + Polycarbonate window, IP67 NEMA4X
    9 Special version, TSP-no. to be spec.
    A Compact Alu, IP67 NEMA4X
    B Compact stainless, IP67 NEMA4X
    C Wall Alu, IP67 NEMA4X
    G Field Alu, IP67 NEMA4X
    P Compact Alu, IP67 NEMA4X, HE HE= harsh environment
    R Compact stainless, IP67 NEMA4X, HE HE= harsh environment
    S Wall Alu, IP67 NEMA4X, HE HE= harsh environment
    T Field Alu, IP67 NEMA4X, HE HE= harsh environment
      Cable, Remote Version:
    0 Not used
    1 5m/15ft coil and signal cable
    2 10m/30ft coil and signal cable
    4 ..... m coil and signal cable
    5 ..... ft coil and signal cable
    9 Special version, TSP-no. to be spec.
      Cable Entry:
    9 Special version, TSP-no. to be spec.
    A Gland M20 (EEx d > thread M20)
    B Thread NPT 1/2
    C Thread G 1/2
    E Gland G 1/2", Ex d Shimada
    K Bus plug + gland M20
    L Bus plug + thread NPT 1/2
    M Bus plug + thread G 1/2
    Q 2 x Bus plug + gland M20
    R 2 x Bus plug + thread NPT 1/2
    S 2 x Bus plug + thread G 1/2
    X Not used, sensor only
      Power Supply; Display:
    9 Special version, TSP-no. to be spec.
    X Sensor only
      Adjustment; Software Feature:
    9 Special version, TSP-no. to be spec.
    X Sensor only
      Output, Input:
    9 Special version, TSP-no. to be spec.
    X Sensor only
      >Design:
    CA Process connection short
    CB Process connection short, Ra<0.38um
      >>Marking:
    Z1 Tagging (TAG), see additional spec.
    Z2 Bus address, see additional spec.
      DKH- Promag H, mounting set
    A mounting set includes 2 process
    connections incl. screws and the
    corresponding seals.

     
      Nominal Diameter:
    02 DN02 1/12"
    04 DN04 5/32"
    08 DN08 5/16"
    15 DN15 1/2"
    1F DN150 6"
    1H DN100 4"
    1Z DN125
    22 DN25 1" ODT, SMS, ANSI, ISO pipes
    26 DN25 DIN, JIS pipes
    40 DN40 1 1/2"
    50 DN50 2"
    65 DN65 2 1/2"
    80 DN80 3"
      Process Connection:
    99 Special version, TSP-no. to be spec.
    AA Welding nipple EN ISO1127, 316L/1.4404
    AB Welding nipple ODT/SMS, 316L/1.4404, O= O-ring
    FA PN40, 316L/1.4404, flange EN1092-1
    FB Cl.150, 316L/1.4404, flange ANSI B16.5
    FC 20K, SUS 316L, flange JIS B2220
    FD PN16, PVDF, flange EN1092-1 (DIN2501)
    FE Cl.150, PVDF, flange ANSI B16.5
    FF 10K, PVDF, flange JIS B2220
    GA Male thread ISO228, 316L/1.4404
    GB Female thread ISO228, 316L/1.4404
    GE Hose adapter ID=13mm, 316L/1.4404
    GF Hose adapter ID=16mm, 316L/1.4404
    GH Hose adapter ID=19mm, 316L/1.4404
    GJ Adhesive fitting tube 1/2", PVC
    GK Adhesive fitting 20x2mm tube, PVC
    HA Welding nipple EN10357, 1.4404/316L (DIN11850)
    HB Welding nipple ODT/SMS, 316L/1.4404
    HC Clamp ISO2852, 316L/1.4404
    HD Clamp DIN32676, 316L/1.4404
    HE Tri-Clamp, 316L/1.4404
    HG DIN11851, 316L/1.4404
    HH Aseptic DIN11864-1A, 316L/1.4404
    HJ Aseptic DIN11864-2A, 316L/1.4404
    HK SMS1145, 316L/1.4404
    HL ISO2853, 316L/1.4404
    HN Welding nipple ASME BPE, 1.4404/316L
    HP Welding nipple ISO2037, 1.4404/316L
      Seal:
    9 Special version, TSP-no. to be spec.
    A O-ring, EPDM
    B O-ring, Viton
    C O-ring, Kalrez
    F Aseptic shape, EPDM
    G Aseptic shape, Viton
    H Aseptic shape, Silicone
      Additional Test, Certificate:
    1 w/o
    2 Mat. certificate (flange)
    9 Special version, TSP-no. to be spec.
      >Design:
    CA Process connection short
    CB Process connection short, Ra<0.38um
    CC Process connection old installatiion
      DK5G- Promag H/Dosimag, seal set
      Nominal Diameter:
    02 DN02 1/12"
    04 DN04 5/32"
    08 DN08 5/16"
    15 DN15 1/2"
    1F DN150 6"
    1H DN100 4"
    1Z DN125
    22 DN25 1"
    26 DN25 DIN
    40 DN40 1 1/2"
    50 DN50 2"
    65 DN65
    80 DN80 3"
      For Product:
    B Promag 10H**, 23H**, 50H**, 53H**, 55H**
      Seal:
    9 Special version, TSP-no. to be spec.
    A Aseptic shape
    B O-Ring for 1.4404/316L process connection
    C O-Ring for PVC + PVDF process connection
      Material:
    99 Special version, TSP-no. to be spec.
    AB 2x EPDM
    BB 2x FKM (Viton)
    DB 2x VMQ (Silicone)
    EB 2x Kalrez
      >Design:
    CA Short
      DK5HB- Promag H, distance disc
    The set includes 2 distance discs incl.
    screws and 2 seals.
    For dimensions refer to the technical
    documentation.
      Nominal diameter:
    1H DN100 4"
    80 DN80 3"
      Process Connection:
    99 Special version, TSP-no. to be spec.
    HS Distance disc
      Seal:
    9 Special version, TSP-no. to be spec.
    F Aseptic shape, EPDM
    G Aseptic shape, Silicone
      DK5HM- Promag H, wall mounting set
      Nominal Diameter:
    15 DN15 1/2"
    22 DN25 1"
    26 DN25 DIN
    H2 DN02 1/12"
    H4 DN04 5/32"
    H8 DN08 5/16"
      DK5HW- Promag H, weld in tool
      Nominal Diameter:
    15 DN02 - DN15 1/12" - 1/2"
    1F DN150 6"
    1H DN100 4"
    1Z DN125
    22 DN25 1"
    26 DN25 DIN
    40 DN40 1-1/2"
    50 DN50 2"
    65 DN65 2-1/2"
    80 DN80 3"
      Material:
    A 1.4301
      DK5HA- Promag H, adapter set
    Replacement of sensor Promag A or
    Promag H DN 25.
    The set includes 2 adapters and 2 seals.
    For dimensions refer to the technical
    documentation.
      Nominal Diameter:
    15 DN 15 1/2"
    22 DN 25 1"
    26 DN 25 DIN
    H2 DN 02 1/12"
    H4 DN 04 5/32"
    H8 DN 08 5/16"
      Process Connection:
    99 Special version, TSP-no. to be spec.
    FA DN15 PN40, 316L/1.4404, Promag A Flange EN1092-1 (DIN 2501)
    FC DN15 20K, 316L/1.4404, flange JIS B2220
    HC Clamp ISO2852, 316L/1.4404
    HH DIN11851, 316L/1.4404
    HK SMS1145, 316L/1.4404
    HL Welding nipple EN10357, 1.4404/316L (DIN11850)
    HM Welding nipple ODT/SMS, 316L/1.4404
      Seal:
    9 Special version, TSP-no. to be spec.
    A O-ring, EPDM
    B O-ring, Viton
    C O-ring, Kalrez
    F Aseptic shape, EPDM
    G Aseptic shape, Viton
    H Aseptic shape, Silicone
      Additional Test:
    1 w/o
    9 Special version, TSP-no. to be spec.
      DK5HR- Promag H, grounding ring
    The grounding ring set includes
    2 grounding rings
      Nominal Diameter:
    15 DN15 1/2"
    22 DN25 1"
    26 DN25 DIN
    H8 DN2-DN8 1/12" - 5/16"
      Material:
    1 1.4435/316L, (Electrodes 316L/1.4435)
    2 Alloy C-22, (Electrodes Alloy C-22)
    5 Tantalum (Electrodes Tantalum)
      Seal:
    0 Not used
    9 Special version, TSP-no. to be spec.
      FXA193- Serviceinterface FXA193
    The service interface connects the
    service port of Proline and ToF devices
    with the serial interface RS 232C
    (9 pin.) of a personal computer.

    Contents of delivery:
    - Serviceinterface with RS 232C
    connection cable (9 pin.)
    - FXA "USB" cable, the additional
    power supply for FXA193 from USB-port
    of the PC.

     
      Approval:
    9 Special version, TSP-no. to be spec.
    A For use in non-hazardous area
    B ATEX II (1) GD
    C CSA/FM Class I Div. 1
    D ATEX, CSA, FM
      Connection Cable:
    9 Special version, TSP-no. to be spec.
    A Proline device
    B ToF device
    E Proline and ToF device
    F Ex two-wire device
    G Proline device and Ex two-wire device
    H Proline, ToF and Ex two-wire device
    X Without connection cable

 

© Copyright 2011 Pitesco Vietnam, All right reserved.
Địa chỉ : 21 Đường 12 Khu Dân Cư Vạn Phúc , Phường Hiệp Bình Phước, Quận Thủ Đức

Điện thoại : 0979.349.375

Email : tu@pitesvietnam.com

Website : www.flowmeters-vietnam.com