AMC2100-AC-CP-HT-NN, ALIA, Bộ hiển thị lưu lượng, ALia Vietnam, Pitesco Vietnam  

Đăng bởiAdmin

AMC2100 Series

AMC2100-AC-CP-HT-PT

Price : Contact Us

 

 

 

AMC2100 Series

 


The Aliamag AMC2100 series converter is a microprocessor based intelligent transmitter that can be paired with any of the Alia AMF series sensors. The unit features multiple display parameters including flow rate, flow total, diagnostics, programming and troubleshooting.

 

FEATURES

 

 

 Three line LCD display Flow Rate / Totalizer
 Accuracy of +/-0.4% value of reading
 Bi-directional flow measurement, current and pulse output
 Large digital display
 Records up to 99 power on/off time
 MODBUS/HART communication

 

SPECIFICATION

 

 

Excitation:

Keyboard:

DC pulsed

3 external keys for programming

Display:

and display control

3 lines LCD with illumination

Low Flow Cutoff:

Line 1

0 to 9.9 %

11 digit totalizer for forward flow

Data logger Function:

11 digit totalizer for reverse flow

99 times flowrate records for power on/off

11 digit totalizer for difference

Record Data:

Line 2

Date/Time when Power on/off

5 digit flowrate / velocity / % / mA / HZ

Flow rate when Power on/off

Line 3

Totalizer when Power on/off

Parameter / Query / Clr tot / Query LOG

Damping:

Alarm, Guidance

0 to 99 Seconds

Unit

Density Setting:

M3/H, L/H, Kg/H, T/H, L/min, M3/min, GPH

0.1 to 9.99 g/cm3

GPM, ML/H, ML/m, ML/sec

Self Diagnosis:

Measuring Range:

The following error message are

Min.  0 to 0.15 m/s

displayed if failure occurs

Max. 0 to 15 m/s

- Coil failure

Accuracy:

- Power failure

+/-0.4% read-out values (Velocity >=0.5 m/s)

- Overranged output

+/-0.002 m/s (Velocity < 0.5 m/s)

- Internal error

Repeatability:

- Overflow

+/-0.1% read-out values

- Empty pipe

Current Output:

Cable Entry:

4-20 mA (Isolated)

Standard :PG11 Option:1/2"NPTF

Load

Protection Class:

Max. 600

IP 65

Pulse output:

Ambient Temperature:

Open collector

-25 to +65 oC

Rating

Material:

3 to 30 VDC, 20 mA Max.

Aluminum Alloy

Pulse Rate:

Power Supply:

1)Scale pulse (Pusle/M3, Pulse/L, Other)

90-260 VAC, 50/60 Hz

2)Frequency: 0-5000 Hz

24VDC +/-10% (Option)

Pulse Width:

Power Consumption:

50% of band width

3-17 W (Dependent on sensor size)

Alarm:

Weight:

High/Low with open collector output

1.4 Kg

Rating

Mounting:

3 to 30 VDC, 20 mA Max.

Wall mounting

Communication:

Bracket on 2" pipe

RS 485 (MODBUS Protocol)

 

HART signal (Compatible)

 

Data Storage:

 

Operation parameters and totalizer

 

figures are stored by EEPROM for more

 

than 10 years

 

© Copyright 2011 Pitesco Vietnam, All right reserved.
Địa chỉ : 21 Đường 12 Khu Dân Cư Vạn Phúc , Phường Hiệp Bình Phước, Quận Thủ Đức

Điện thoại : 0979.349.375

Email : tu@pitesvietnam.com

Website : www.flowmeters-vietnam.com