CS INSTRUMENTS VIETNAM
The residual oil content sensor OILCHECK measures the vaporous residual oil content in the compressed air. For stationary solution we offer you a combination with the chart recorder DS 400.
The residual oil content sensor OILCHECK measures the vaporous residual oil content in the compressed air. For a mobile solution we offer you a combination with the particle counter PC 400 and mobile chart recorder DS 500 mobile.
The highly precise optical particle counter PC 400 measures particles from a size of 0.1 µm and is therefore suitable for monitoring of the compressed air quality class 1 ISO 8573.
PC 400 particle counter up to 0.1 µm for compressed air and gases in a service case.
for measurements from 0...10 and 0...16 bar with accuracy of full scale max. 1% or max. 0,5%.
for measurements from 0...40 bar with accuracy of full scale max. 1% or max. 0,5%.
for measurements from 0...1.6 bar absolute with accuracy of full scale max. 0,5%.
for measurements from 0...100 bar with accuracy of full scale max. 0,5 %.
for measurements from 0...250 bar with accuracy of full scale max. 0,5 %.
for measurements from 0...400 bar with accuracy of full scale max. 0,5 %.
for measurements from -1...+15 bar with accuracy of full scale max. 0,5%.
for measurement of differential pressure 0...400 mbar with accuracy of full scale 0.075%.
Leakages are the reason for the biggest waste of energy in compressed air systems. Several studies show that 30% of the cost of compressed air can be saved by eliminating leakages. Therefore, it is a must to detect and eliminate leakages frequently. Our LD-Series will give you all the function needed to detect leakages and measure the consequences in terms of energy consumption and wasted money.
Typical applications of our measuring instruments in this section are leakage detection in compressed air systems and leak testing of unpressurized systems.
is the advancement of the proven LD 300 and even the smallest leakages can be detected even from distances of several meters.
The set includes a robust impact-proof transportation case which contains all necessary components and accessories.
With the integrated camera it is possible to take photos of the leakage areas. A software allows simple report generation on your computer. Available end of 2017.
Air flow meters and mass flow meters from CS Instruments work according to the calorimetric measuring principle. This means, while measuring the thermal mass flow or standard volume flow, no additional temperature and pressure compensation is necessary. The standard volume is a common volumetric unit used to compare gas quantities at different pressures and temperatures. In order to meet various standards, the reference conditions can be set directly on the display of the flow meter. Thus, our flow meters provide consumption and flow measurement within the standard our customers wish to use them.
If you need further advice simply contact us and we will help you finding the correct flow meter for your individual application scenario.
in measurement of compressed air and gases. ATEX version available for applications in explosive areas.
The measuring sections are available in flanged version or with R resp. NPT thread.
RS 485 interface, Modbus RTU, 4...20 mA analogue output for m³/h, Pulse output for m³.
Our flow meter for compressed air and gases with newly developed evaluation electronics records all measured values digitally.
The PI 500 is an all-purpose hand-held measuring instrument for many applications in the industry.
consisting of: Chart recorder DS 400 and flow sensor VA 500
available in a robust housing with and without display. Depth scale for accurate installation. Usable from 1/2" to 12" (DN 300).
Intelligent solutions for flow measurement of compressed air and gases. With and without flange available.
Up to 12 optional sensors can be connected. 7" colour screen with touch panel.
Energy analysis according to DIN EN ISO 50001, flow measurement, leakage calculation at compressed air systems.
3.5" graphic display with touch screen. Option integrated data logger. Up to 4 sensor inputs. Option Ethernet / RS 485 interface.
for energy analysis, flow measurement, leakage calculation at compressed air systems.
serves for determination of the flow direction of compressed air and gases especially in closed circular pipelines and detects smallest changes <0.1 m/s.
Measuring section made of stainless steel 1.4301 incl. ball valve, up to DN 65 (R2 1/2") with external thread, from DN 80 with weld neck flange according to DIN 2633.
If there is no measuring site with 1/2" ball valve present it can be set up by means of spot drilling collars.
By means of a special drilling device a measuring site with 1/2" ball valve can be easily set up within a few minutes.
The supplementary device "high-pressure protection" serves for a safe installation and fastening of the CS sensors VA 400 under pressure.
enables a quick, easy and accurate measurement of the wall thickness of pipes.
Dew point measurement and dew point monitoring in compressed air systems is essential. Drying of granulate in plastics technology, the generation and usage of various technical gases (N2, O2, Ar, H2) and a lot more applications require dew point measuring equipment. With our reliable dew point meters we are helping customers worldwide to ensure the required product quality in compressed air and gas systems.
For any questions concerning our dew point meters feel free to contact one of our local experts by using our contact form or just give us a call.
is the ideal portable service instrument for dew point measurement for all types of dryers down to -80°Ctd dew point.
disposes of all functions of DP 500 and has a additional freely assignable sensor input.
Ideal for the monitoring of refrigeration or adsorption dryers.
Ideal instrument for dew point measuring for all kinds of dryers.
for residual moisture measurement after desiccant dryers/ membrane dryers from -80 to 20°Ctd. New: with Modbus-RTU interface.
with the digital process meter DS 52 and the dew point sensor FA 510 with a measuring range from -80 to 20°Ctd.
From -20 to 50°Ctd. New: with Modbus-RTU interface.
with the digital process meter DS 52 and the dew point sensor FA 510 with a measuring range from -20 to 50°Ctd.
from -80 to 20°Ctd. Extremely long-term stable. Analogue output 4...20 mA.
The measuring range of -80...20°Ctd makes the DS 52-set with alarm the ideal dew point monitor with analogue output 4...20 mA.
from -20 to 50°Ctd. Extremely long-term stable. Analogue output 4...20 mA.
The measuring range of -20...50°Ctd makes the dew ponit set DS 52 with alarm the ideal dew point monitor with analogue output 4...20 mA.
is the ideal instrument for dew point measuring for all kinds of dryers.
FA 300-2 measures the dew point resp. the pressure dew point in explosive areas of Zone 1. Protection class: FA 300-2 Ex: I 2G Ex ia II C T4.
for compressed air up to 16 bar
for compressed air up to 350 bar
up to 250 mbar
is screwed onto the dew point sensor and therefore enables an easy and low-priced possibility for on-site control and calibration down to -20°Ctd.
in gases / air up to 100 bar