Proline Promag 10W Electromagnetic flowmeter
Model : 10W65-UC0A1AA0A5AA
[65] Nominal Diameter: DN65
[U] Liner: Polyurethane
[C] Process Connection: PN16 EN1092-1(DIN2501)
[0] Electrodes / materia : Measuring, reference and EPD electrodes / 316L SS
[A] Calibration: 3-point calibration, 0.5%
[1] Certificates: Standard, no certificate
[A] Approvals: Non-hazardous area
[A] Housing: Compact Alu, IP67 NEMA4X
[0] Cable, Remote Version: Not used
[A] Cable Entry: Gland M20
[5] Power Supply; Display: 20-28VAC / 11-40VDC; 2-line,push buttons
[A] Adjustment; Software Feature: Factory setup; basic version
[A] Output, Input: 4-20mA HART + pulse passive
Price : Contact Us
Pites Co.,Ltd
Hotline : |
Email : sales1@pilz-vietnam.com
Add : D5 Mieu Noi Resident, Dinh Tien Hoang St, W.3, Binh Thanh Dist, HCM City, Viet Nam
Tel : /75
Fax : 08 3517 6476
Web: www.pitesco.com
Proline Promag 10W Electromagnetic flowmeter
Sensor with degree of protection IP68 (Type 6P enclosure) with a highly cost-effective transmitter
Liquids
Measuring Principle |
Electromagnetic |
Product headline |
The sensor with degree of protection IP68 (Type 6P enclosure) combined with a highly cost‐effective transmitter. The specialist in the water and wastewater industry for the most demanding applications. |
Sensor features |
Secure, reliable long‐term operation – robust and completely welded sensor. Energy‐saving flow measurement – no pressure loss due to cross‐section constriction. Maintenance‐free – no moving parts. International drinking water approvals. Degree of protection IP68 (Type 6P enclosure). |
Transmitter features |
Cost‐effective – designed for easy applications and direct integration. Safe operation – display provides easy readable process information. Fully industry compliant – IEC/EN/NAMUR. 2‐line display with push buttons. Device in compact or remote version. |
Nominal diameter range |
DN 25...2000
1"...78" |
Max. measured error |
±0.5% |
Measuring range |
0...110'000 m3/h |
Max. process pressure |
PN6...40
Cl 150...300
JIS 10...20K
AWWA Class D
AS 2129 Table E
AS 4087 PN16 |
Medium temperature range |
-20...+80°C
(-4...+176°F) |
Degree of protection |
IP 67 (Nema 4x)
IP 68 (Nema 6P) |
Display/Operation |
Two line display
Push buttons |
Outputs |
4...20mA + pulse,-/status (configurable) |
Digital communication |
HART |
Hazardous area approvals |
FM
CSA |
Accessories
Nr |
Order code |
Specification |
|
DK5WM- |
Transmitter Promag, mounting set
10/50/51/53/55/800
|
Application: |
B |
Remote, field
Tube 3/4 - 3inch |
|
All Spare parts
Nr |
Order code |
Specification |
A |
50104751 |
Kit Main-PCB PMAG10 85-250VAC |
A |
50104752 |
Kit Main-PCB PMAG10 20-28VAC 11-40VDC |
A |
71098237 |
Kit Main-PCB 10 85-250VAC HE
HE = harsh environment
|
A |
71098239 |
Kit Main-PCB 10 20-28VAC 11-40VDC HE
HE = harsh environment
|
3 |
50104749 |
Kit 10 fuses 1.0 A/250 slow |
3 |
50104750 |
Kit 10 fuses 1.6 A/250 slow |
B |
50104745 |
Kit display 10/91W with keyboard |
C |
50104754 |
Kit connec. board PMAG10 FS elect |
C |
71098240 |
Kit connec. board 10 FS Elekt HE
HE = harsh environment
|
D |
50098018 |
Kit connection board D/E/L/P/S/W FS
Usage:
10/50/51/53/55/400/800
|
D |
71039497 |
Kit connection board D/E/L/P/S/W FS HE
Usage:
10/50/53/55
HE = harsh environment
|
1 |
50108138 |
Kit Terminal Block 10/91W |
13 |
50094038 |
Kit Cover Connection terminal
10/5X/40/8X/93/65/400/800
|
9 |
50094038 |
Kit Cover Connection terminal
10/5X/40/8X/93/65/400/800
|
5 |
50104746 |
Kit cover 10/91W with window |
6 |
50104747 |
Kit cover 10/91W blind version |
10 |
50103658 |
Kit 10 cable glands M20x1,5 grey |
10 |
50096840 |
Kit 10 cable glands M20x1,5 |
10 |
50098041 |
Kit 10 ext. M20x1.5/G 1/2" (plug PVC) |
10 |
50098042 |
Kit 10 ext. M20x1.5/NPT 1/2" (plug PVC) |
4 |
50104748 |
Kit PCB/Display carrier 10/91W |
7 |
50104753 |
Kit housing gaskets PMAG10 housing |
8 |
50097147 |
Kit Ground terminal/Cover clamp
10/23/65/72/73/91W/92F/8FF/8FE/8CM
|
2 |
50099102 |
Kit Bushing to field/SS-housing |
15 |
50098019 |
Kit parts housing FS Stnd/HT
Usage:
10/50/51/53/55/400/800
Sensor: D/E/H/L/P/S/W
|
12 |
50098020 |
Kit parts housing compact Stnd/HT
Usage:
10/23/50/51/53/55
Sensor: D/E/H/L/P/S/W
|
14 |
50098023 |
Kit housing gasket FS Stnd/HT
Usage:
10/50/51/53/55/400/800
Sensor: D/E/L/P/S/W
|
11 |
50098024 |
Kit housing gasket compact Stnd/HT
Usage:
10/23/50/51/53/55
Sensor: D/E/L/P/S/W
|
|
50098801 |
Fieldcheck verification/simulation syst.
Universal verification and simulation
system for routine verification of
all E+H Proline flowmeters (incl.
outputs) and simulation of the primary
sensor signals.
By means of the software FieldCare
device set up, the verification results
can easily be documented.
To connect Fieldcheck to a personal
computer a serial interface cable
(RS 232C) is included.
Delivery with:
Power supply unit 85-260 VAC
NiMH-AccuPack
Softcase
Connection cable for Simubox
Connection cable Fieldcheck/Proline dev.
Test leads current/frequency
Serial interface cable (RS 232C)
|
|
10XXX- |
Promag 10, transmitter
|
Application: |
XXX |
Promag 10W, 10P, 10H, 10D, 10L, 10E |
|
Version: |
XX |
Transmitter only |
|
Approval: |
A |
Non-hazardous area |
R |
FM NI Cl. I Div. 2 / CSA Cl. I Div. 2 |
|
Housing: |
A |
Compact Alu, IP67 NEMA4X |
G |
Field Alu, IP67 NEMA4X |
P |
Compact Alu, IP67 NEMA4X, HE
HE= harsh environment |
T |
Field Alu, IP67 NEMA4X, HE
HE= harsh environment |
|
Cable, Remote Version: |
0 |
Not used |
2 |
10m/30ft coil and signal cable |
4 |
..... m coil and signal cable |
5 |
..... ft coil and signal cable |
|
Cable Entry: |
A |
Gland M20 |
B |
Thread NPT 1/2 |
C |
Thread G 1/2 |
|
Power Supply; Display: |
0 |
85-250VAC; w/o display,
Remote configuration |
1 |
20-28VAC / 11-40VDC; w/o display
Remote configuration |
4 |
85-250VAC; 2-line, push buttons |
5 |
20-28VAC / 11-40VDC; 2-line,
push buttons |
|
Adjustment; Software Feature: |
A |
Factory setup; basic version |
|
Output, Input: |
A |
4-20mA HART + pulse passive |
|
|
DK5CA- |
Promag, cable remote version
10/50/51/53/55/400/800
1 kit includes 1 coil cable and
1 signal cable
|
Cable, Remote Version: |
2 |
10m/30ft |
4 |
..... m |
5 |
..... ft |
|
Approval: |
A |
Non-hazardous area + ATEX II 3G, FM/CSA |
|