Vietnam
English
+84 979.349.375
Chào mừng quý khách đến với Flowmeters Vietnam
Electromagnetic Flowmeter
AMC2100-AC-CP-HT-PT
AMC2100 Series
The Aliamag AMC2100 series converter is a microprocessor based intelligent transmitter that can be paired with any of the Alia AMF series sensors. The unit features multiple display parameters including flow rate, flow total, diagnostics, programming and troubleshooting.
FEATURES
Three line LCD display Flow Rate / Totalizer Accuracy of +/-0.4% value of reading Bi-directional flow measurement, current and pulse output Large digital display Records up to 99 power on/off time MODBUS/HART communication
SPECIFICATION
Excitation:
Keyboard:
DC pulsed
3 external keys for programming
Display:
and display control
3 lines LCD with illumination
Low Flow Cutoff:
Line 1
0 to 9.9 %
11 digit totalizer for forward flow
Data logger Function:
11 digit totalizer for reverse flow
99 times flowrate records for power on/off
11 digit totalizer for difference
Record Data:
Line 2
Date/Time when Power on/off
5 digit flowrate / velocity / % / mA / HZ
Flow rate when Power on/off
Line 3
Totalizer when Power on/off
Parameter / Query / Clr tot / Query LOG
Damping:
Alarm, Guidance
0 to 99 Seconds
Unit
Density Setting:
M3/H, L/H, Kg/H, T/H, L/min, M3/min, GPH
0.1 to 9.99 g/cm3
GPM, ML/H, ML/m, ML/sec
Self Diagnosis:
Measuring Range:
The following error message are
Min. 0 to 0.15 m/s
displayed if failure occurs
Max. 0 to 15 m/s
- Coil failure
Accuracy:
- Power failure
+/-0.4% read-out values (Velocity >=0.5 m/s)
- Overranged output
+/-0.002 m/s (Velocity < 0.5 m/s)
- Internal error
Repeatability:
- Overflow
+/-0.1% read-out values
- Empty pipe
Current Output:
Cable Entry:
4-20 mA (Isolated)
Standard :PG11 Option:1/2"NPTF
Load
Protection Class:
Max. 600
IP 65
Pulse output:
Ambient Temperature:
Open collector
-25 to +65 oC
Rating
Material:
3 to 30 VDC, 20 mA Max.
Aluminum Alloy
Pulse Rate:
Power Supply:
1)Scale pulse (Pusle/M3, Pulse/L, Other)
90-260 VAC, 50/60 Hz
2)Frequency: 0-5000 Hz
24VDC +/-10% (Option)
Pulse Width:
Power Consumption:
50% of band width
3-17 W (Dependent on sensor size)
Alarm:
Weight:
High/Low with open collector output
1.4 Kg
Mounting:
Wall mounting
Communication:
Bracket on 2" pipe
RS 485 (MODBUS Protocol)
HART signal (Compatible)
Data Storage:
Operation parameters and totalizer
figures are stored by EEPROM for more
than 10 years
© Copyright 2011 Pitesco Vietnam, All right reserved. Địa chỉ : 21 Đường 12 Khu Dân Cư Vạn Phúc , Phường Hiệp Bình Phước, Quận Thủ Đức
Điện thoại : 0979.349.375
Email : tu@pitesvietnam.com