Insertion probe, type K, For soft media, air, gases and liquids
Measuring range: -65 ... +1000 °C Response time: t90 = ca. 5 sec.
Price : Contact Us
big white teflon handle water- and steam-tight, stainless steal anti-buckling, 1 m teflon calbe, DIN plug, teflon handle Use for canteen kitchen, backeries, butcher´s shops, etc.
V4A tube with Ø 1.5 mm slim insertion tip, small teflon handle, stainless steel kink protection, 1 m teflon cable, miniature flat plug
Response time T90: approx. 3 s Use for: canteen kitchen, backeries, butcher´s shops, etc.
Please order article separately per email. State input signal and measuring range when ordering.
Measuring Range: -50...+400 °C or -200 ...+600 °C (with insulated sheath tube) Sensor: Pt100 DIN class B, isolated (Pt1000 on request) Tube material: V4A Probe length FL: 100mm (stand.) or custom-made Extension length HL: 0mm (stand.) or 50mm (for temp. > 400 °C) Diameter D: 6mm (standard) or 0.5mm, 1.0mm, 1.5mm, 3mm, 4mm, 5mm, or 8mm Thread G:: G1/2" (stand.) or without thread Connection head: DIN B-head (aluminium) wth terminal socket Special design: with output signal 4-20mA Note: Depending on the wanted version, there can be surcharges Ordering example: GTF 103 NiCr-Ni, 0/+800 °C, FL=100mm, HL=50mm, D=6mm, G1/2"
Low-priced monitoring and controlling of temperature and humidity. With a single 2-wire twisted pair cable(e.g. bell wire) the humidity- / temperature sensor EBHT-1R will be connected with the EB 3000. The maximum allowable distance between sensor and controlling device amounts to 500m. Range of application:
Design Type: Type: PFA Pt 100, flexible sealed Cable length: 1 m Connection: 4-wire-connection (4 x 0.14mm² nickel-plated copper) Nominal diameter: 2.1 mm Technical Data: Temperature range: -60.0 ... +250.0°C Accuracy: DIN class A
Advantages:
Design Type: Type: PFA Pt 100, flexible sealed Cable length: 3 m Connection: 4-wire-connection (4 x 0.14mm² nickel-plated copper) Nominal diameter: 2.1 mm Technical Data: Temperature range: -60.0 ... +250.0°C Accuracy: DIN class A
The EASYLOG 80CL can be configured, started and stopped by it's buttons. lt is possible to record max. 64 recording sequences (=start/stop processes) with max. 200.000 data sets (humidity/temperature/air pressure). The device additionally supports the display of various units, which are relevant for the air conditioning technology: wet bulb temperature, dew point temperature, enthalpy. and atmospheric humidity.
Functional description: The software EasyControl resp. the alarm module EBUW 232 A enquires the EasyBus and therewith all connected sensor modules for occurring alarm conditions. When a value falls below/above a alarm limit, this is signaled to the alarm module EBB 2 OUT, which switches the relevant relays.
Technical Data: Power supply: via EasyBus Relays: 2 changeover relays (volt-free) Switching raction: < 1 second Switching power: 250 V AC / 16A Triggering: via EBUW 232 A or software EasyControl Easybus connection: terminal screw, 2-pin, protected against polarity reversal
Technical Data: Measuring range: 0 … 2000 ppm CO2 Measuring principle: Infrared principle (NDIR) Accuracy: ± 50 ppm / ± 2 % of meas. value Auxiliary energy: 12 … 30 V DC, max. 500 mA Interface: EASYBus Housing: 82 × 80 × 55 mm (H × W × D) Weight: Ca. 225 g Note: Connecting an external power supply of 12-36VDC, the EBG - CO2 - 1R could be used as display, without serial converter EBW1, EB3000 etc.
Concentric 2-pole stainless steel electrode (1.4404, 1.4435) with integrated temperature sensor Dimensions: Ø12mm, 75mm long, cable length ca. 1m
Features:
Anwendung:
Technical Data:
Measuring ranges: pH Redox / mV Temperature rH
-2,000 ... 16,000 pH -2000 ... 2000 mV -1000,0 ... 1000,0 mV -5,0 ... 150,0 °C 0,0 ... 70,0 rH
The GW 110PB connects from the EASYBus to the PROFIBUS.
A SPS, PLC, can easily gather measuring values or other data from an EASYBus module. You can connect and talk to any EASYBus module.
Requirements:
Scope of Supply:
Rotation speed measuring device via light and reflecting label or measuring tip; velocity and length measurement via measuring wheel The handheld tachometer rotaro 3 is useful at the installation and setup of plants and machinery as well as for service application, monitoring production processes or use at development laboratory. The rotaro 3 can measure rotary speed of for example motors, turbines, pumps as well as stirring devices, centrifuges and haulage installations,
Specifications:
optical / mechanical 1 ... 99999 min-1
5-digit LCD display with 10 mm height of digits and floating point at range change, low-battery warning
min- / max- value memory, average and last value
Rotation speed measuring device via light and reflecting label
The handheld tachometer ecotach is useful at the installation and setup of plants and machinery as well as for service application, monitoring production processes or use at development laboratory. The rotaro 3 can measure rotary speed of for example motors, turbines, pumps as well as stirring devices, centrifuges and haulage installations.
1 ... 60.000 rpm
5-digit LCD display for measuring value with floating point, measuring unit, trigger signal, low-battery warning
automatically after 30 s
Application:
Specification:
Number of measuring ranges:
Interface / ext. supply
Technical Data: Measuring range: 0 … 300 ppm CO Measuring principle: electrochemical, permanent measuring Response Time T90: < 60 s Auxiliary energy: 14 … 30 V DC, max 50 mA Interface: EASYBus Dimensions Housing: 82 × 80 × 55 mm (L X B x H) Weight: approx. 20 g
Technical Data: Power supply: 12 V DC ± 10 % / 150 mA Relays: 2 changeover relays (volt-free) Switching raction: < 0,1 second Switching power: 250 V AC / 16A Triggering: via EBUW 232 A or software EasyControl Easybus connection: terminal screw, 2-pin, protected against polarity reversal
Microprocessor controlled, digital pressure transducer with display and operation via 3 buttons. With freely scalable analog output that can be switch between 4-20 mA and 0-10 V.
Suitable for: air and non-aggressive gases
Area of application:
Relative pressure range:
Measuring range
MP-S-MR0
0,0 … 100,0 mbar rel.
MP-S-MR1
0,0 … 500,0 mbar rel.
MP-S-MR2
0 … 1000 mbar rel.
MP-S-MR3
0 … 2000 mbar rel.
MP-S-MR4
0 … 5000 mbar rel.
Absolute pressure range:
MP-S-MA0
0 … 1100 mbar abs.
MP-S-MA1
0 … 2000 mbar abs.
Optimized special ranges possible: see option - MBS (e.g. -350 ... +350 mbar)
Typ. accuracy:
±0,15 % FS (lin.), ±0,6 % FS (hysteresis and temperature 0 ... 70 °C)
Relative fine pressure range:
MP-F-MR0
0,000 … 1,000 mbar rel.
MP-F-MR1
0,00 … 10,00 mbar rel.
MP-F-MR2
0,00 … 20,00 mbar rel.
Optimized special ranges possible: see option - MBF (e.g. -15 ... +15 mbar)
±0,35 % FS (lin.), ±0,6 % FS (hysteresis and temperature 0 ... 70 °C)
Feature:
Applications:
Measuring ranges:
Temperature:
-25.0°C ... +70.0 °C
Air humidity:
0.0 ... 100.0 % r.F. (recommended range: 11 ... 90 % RH)
Air pressure:
10.0 ... 1100.0 mbar
Dew point temperature Td:
Wet bulb temperature Twb:
Moisture content x:
Absolute humidity d:
Accuracy:
±0,5 % v.MW. ±0,1°C (Pt1000 1/3 DIN B)
±2,5 % r.F. (at range 11 bis 90%)
±1,5 mbar (750...1100 mbar)
Response time:
Display:
4½ -digit, approx. 11 mm high LCD-display with additional displays
Power supply:
9V-Batterie Typ IEC 6F22
Current consumption:
max. 20 ?A at 1 meas. / 60 s (mode SLOW) approx. 70 ?A at 1 meas. / 1 s (mode FAST)
Technical Details: GIM 530 MS Measuring range: -32C ... +530 °C (-20 °F ... +980 °F) Resolution: 0,1 °C (0,1 °F) Response Time (t95): 0,3 sec. Accuracy +/- 1% or +/- 1 °C (highest value should be valid) Emission rate: 0,100 ... 1,000, adjustable Optical resolution D/S: 20:1 (Measuring Distance : Measuring Zone) Dimensions, weight: 190 x 38 x 45 mm, 150 g Scope of supply: Device with battery, operating manual, device bag made of nylon
Classic application of the TA 888 N is flow measurement in ventilation ducts. Due to its high resolution of 0.01 m/s even smallest changes of the flow velocity can be easily and fast detected. The sensor´s small dimensions ensure measurements yet in thin tubes and confined spaces. Further applications are function and dirt checks of filters and exhaust ducts as well as measurements of room air velocity.
Measuring range Flow:
Measuring range Temperature:
Accuracy Flow:
0 ... 1 m/s ±0.25 m/s 1 ... 5 m/s ±0.5 m/s 5 ... 10 m/s ±1.0 m/s 10 ... 15 m/s ±2.0 m/s
Accuracy Temperature:
±1 °C
LCD display
Dimensions:
© Copyright 2011 Pitesco Vietnam, All right reserved. Địa chỉ : 21 Đường 12 Khu Dân Cư Vạn Phúc , Phường Hiệp Bình Phước, Quận Thủ Đức
Điện thoại : 0979.349.375
Email : tu@pitesvietnam.com