Vietnam
English
+84 979.349.375
Chào mừng quý khách đến với Flowmeters Vietnam
EtherNet/IP to Siemens Industrial Ethernet Communication Gateway
Model: PLX31-EIP-SIE
Price : Contact Us
EtherNet/IP to Siemens Industrial Ethernet
PLX31-EIP-SIE
The EtherNet/IP to Siemens Industrial Ethernet gateway offers bi-directional data transfers between the Siemens Industrial Ethernet and EtherNet/IP networks. Our EtherNet/IP Driver uses Class 1 I/O connections or Class 3 Message instructions. Our Ethernet Industrial Ethernet Driver uses Multiple Clients and Servers for faster data throughput. Protocol conversion gateways are the ideal solution for distributed networks when adding a remote rack becomes too costly.
The PLX31-EIP-SIE gateways are stand-alone DIN-rail mounted modules that provide one Ethernet port for communication, allowing for remote configuration and diagnostics. The PLX30 gateways also come with an SD Card slot (SD card optional) for storing configuration files. In the event of a failure the SD card can be transferred to another gateway reducing downtime. These gateways also come with a wide input power range (10 Vdc – 36 Vdc), and an extended temperature range (-25°C to 70°C ). The PLX30 gateways include all the necessary cables required for communication.
Specification
Description
Power Supply
24 Vdc nominal 10Vdc to 36 Vdc allowed Positive, Negative, GND Terminals
Current Load
24 Vdc nominal @ 300mA 10 to 36 Vdc @ 610mA maximum
Operating Temperature
-25°C to 70°C (-13°F to 158°F )
Storage Temperature
-40°C to 80°C (-40°F to 176°F )
Relative Humidity
5% to 95% RH with no condensation
Shock
IEC 60068-2-27; 15G @ 11ms, 3-Axis (Operational) IEC 60068-2-27; 30G @ 18ms, 3-Axis (Non-Operational)
Vibration
IEC 60068-2-6; 5G @ 10Hz to 150Hz
Dimensions (Height x Width x Depth)
Standard: 5.38 in x 1.99 in x 4.38 in (13.67 cm x 5.05 cm x 11.13 cm)
LED Indicators
Configuration (CFG) and Error (ERR) Communication Status Power (PWR) and Hardware Fault (FLT) Network Status (NS) EtherNet/IP Class I or Class III Connection Status Module Status (MS) Module Configuration Status Ethernet Communication Port Link/Activity and 100mbit Serial Communication Port Receive (RX) and Transmit (TX)
Ethernet Port
10/100 Base-T half-duplex RJ45 Connector Electrical Isolation 1500 Vrms at 50 Hz to 60 Hz for 60 seconds, applied as specified in section 5.3.2 of IEC 60950: 1991 Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP] frames-per-second and less than or equal to 5 minutes duration
Serial Port(S)
Note: The number of serial communication ports depends on the gateway type, and the combination of protocols.
Serial Port Isolation
2500 Vrms port signal isolation per UL 1577 serial port communication signal uses RF(Radio Frequency) modulation signal as isolation media, IC chip model is SiliconLabs Si844x(Si8440,Si8441,Si8442).
Shipped With Each Unit
2.5 mm screwdriver, PLX30 DVD, J180 Power Connector, (1 to 4) RJ45-DB9M Serial Adapter Cable (serial protocol), (1 to 4) DB9 to Screw Terminal Adapter (serial protocol), 5’ straight-through Ethernet cable (grey)
© Copyright 2011 Pitesco Vietnam, All right reserved. Địa chỉ : 21 Đường 12 Khu Dân Cư Vạn Phúc , Phường Hiệp Bình Phước, Quận Thủ Đức
Điện thoại : 0979.349.375
Email : tu@pitesvietnam.com